• Vocs on-Line Monitoring System (AQMS-08)
  • Vocs on-Line Monitoring System (AQMS-08)
  • Vocs on-Line Monitoring System (AQMS-08)
  • Vocs on-Line Monitoring System (AQMS-08)
  • Vocs on-Line Monitoring System (AQMS-08)

Vocs on-Line Monitoring System (AQMS-08)

After-sales Service: 1 Year
Warranty: 1 Year
Brand: Scince
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Vocs on-Line Monitoring System (AQMS-08) pictures & photos
Vocs on-Line Monitoring System (AQMS-08)
US $3,400-3,600 / Set
Min. Order: 1 Set
Gold Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Trading Company

Basic Info.

Model NO.
AQMS-08
Customized
Customized
Portable
Non Portable
Gas
Vocs
Type
Laser Gas Analyzer
Detection Parameters
Total Emission Concentration of Voc, Vocs, Tvoc,
Detection Principle
Pid (British Alpha Sensor)
Detection Method
Fixed Pumping Online Long-Term Continuous Detectio
Measuring Range
0-500ppm(μ Mol/Mol)
Discrimination Rate
0.1ppm
Indication Error
≤ 10% F.S
Repeatability
≤±0.5%
Zero Drift
≤ 5% (F.S/Year)
Range Drift
≤ 5% (F.S/Year)
Response Time
≤15 Seconds (T90)
Recovery Time
≤20 Seconds
Explosion-Proof Mark of Detector
Exd II CT6
Transport Package
Wooden Package
Trademark
Scince
Origin
Suzhou, China
Production Capacity
50sets/Month

Product Description

VOCs On-line Monitoring System
Product Profile
    AQMS-08 VOCs On-line Monitoring System is mainly used to monitor whether the emission standards of atmospheric pollutants stipulated by the state are met when volatile organic compounds are continuously discharged.
    According to the source of pollutants, the grid monitoring system of industrial park is established. The regional grid monitoring system adopts the unit grid management method, and according to the concept of "fixing the net, setting the responsibility according to the grid, setting the responsibility according to the people", the regional grid monitoring platform of "horizontal to the edge, vertical to the end" is established, and a number of intelligent environmental protection technologies are applied and integrated. On the basis of comprehensively mastering and analyzing the emission of pollution sources and meteorological factors, the model based on Gaussian algorithm is adopted for development. Real-time statistics of monitoring equipment data of each plant area and monitoring point, and analysis and prediction of the overall emission situation in the region according to the emission situation of each monitoring point and its meteorological conditions. The whole monitor of VOCs emission area is realized,The functions of pollutant diffusion trend estimation, emission source analysis, etc., combined with advanced technologies such as Internet of Things, intelligent acquisition system, geographic information system, dynamic chart system, etc., integrated, shared and developed, and established a comprehensive, refined, information-based and intelligent regional online monitoring platform to achieve comprehensive management of controlling unorganized emission of pollution sources and reducing air pollution. To provide reliable data information and scientific auxiliary management decisions for making energy saving and emission reduction plans.


Vocs on-Line Monitoring System (AQMS-08)Advantages
Adopting PID sensor, the response is sensitive and fast.
Safe operation, no need to use flammable and explosive gases such as hydrogen.
And is suitable for detect VOC gas in various industrial environments.
Built-in full Netcom DTU module, data can be transmitted to EPA.
Real-time test data display by curve.
Automatic unmanned operation of the whole system, simple operation, self-checking and error alarm functions.
Applications
Atmospheric monitoring in chemical plants, power plants, incineration stations, ports, sewage treatment plants and other places.
Technical Parameters
Detection parameters Total emission concentration of VOC, VOCs, TVOC, non-methane total hydrocarbon, benzene series, etc
Detection principle PID (British alpha sensor)
Detection method Fixed pumping online long-term continuous detection
Measuring range 0-500PPM(μ mol/mol) (optional, range not listed can be customized)
Discrimination rate 0.1PPM
Indication error ≤ 10% F.S (actual concentration, higher accuracy requirements are determined according to sensor performance)
Repeatability ≤±0.5%
Zero drift ≤ 5% (f.s/year)
Range drift ≤ 5% (f.s/year)
Response time ≤15 seconds (T90)
Recovery time ≤20 seconds
Explosion-proof mark of detector Exd II CT6
Protection grades Tester IP66, whole machine IP54
Working temperature -20ºC-+200ºC (customized for special requirements)
Working humidity ≤95%RH, no condensation (humidity > 90%RH, condensation can be equipped with filter)
Relative humidity 10%-95%RH, the instrument has built-in full temperature and humidity compensation function
Power supply source AC220V
Vocs on-Line Monitoring System (AQMS-08)Vocs on-Line Monitoring System (AQMS-08)
1. Are you a trading company or manufacturer?
we are a professional tester manufacturer with 25 years of industry experience. Our factory is located in Suzhou, where is only 100 kilometers far away from Shanghai Hongqiao International Airport. It is pretty convenient for you to make a visit.

2. What is the L/T?
The lead time will be between15 and 30 days after deposit payment. If there is stock for the instrument you want, timely shipment will be arranged within 7 days.

3. What is your terms of payment?
Based on our sales policy, T/T 30% as deposit should be paid before order, and 70% balance payment should be completed before shipment. We will provide you with real photos or video of the instrument before balance payment.

4. What is your terms of delivery?
Available in EXW, FOB, CFR and CIF.

5. What is your packing for the tester?
Generally, packed with wooden case. We can do some adjustments in terms of your special requirement.

6. Can the mask tester be certified?
There is certification requirements for mask only, and there has no relevant certification requirements for mask tester, but a calibration report is required. we will provide a calibration report with a randomizer for our mask test instrument. The calibration report is valid for one year. After then, we can also support the corresponding calibration service for small fee.

7. Do you have after-sales service?
We can provide on-site installation and commissioning service for you, but you need to bear the travel expense of our engineer. The warranty period will be one year. Free replacement parts will be supplied during this period. Only accessories and corresponding shipping charges will be charged out of the warranty period.

8. Is there an English interface for your instrument?
Our instrument can be customized on the base of your demand. For example, both mask tester and filter material tester can be displayed in Chinese, English and Korean interfaces. The instruction manual is available in both Chinese and English.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Vocs on-Line Monitoring System (AQMS-08) pictures & photos
Vocs on-Line Monitoring System (AQMS-08)
US $3,400-3,600 / Set
Min. Order: 1 Set
Gold Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Trading Company
Number of Employees
4
Year of Establishment
2017-08-07